Technical Specifications |
Parameters |
Number of channels |
32 digital outputs |
Output configuration |
Current sink |
Output port configuration |
Single 32-bit word |
Output Drive |
600 mA per channel continuous;
3.5 A peak (100 mS max) |
Output ON voltage |
< 550 mV @ 600 mA (incl. std 3’ cable) |
Output ON impedance |
< 0.9 Ohm (including std 3’ cable) |
Output OFF impedance |
> 1 Meg Ohm |
Output OFF leakage |
< 25 µA |
Overvoltage protection |
±40 VDC (reverse current must be limited to 1 A to prevent damage) |
Overvoltage protection |
Current Limit |
50 mA - 2 A |
Overload response time |
10-5000 ms (user programmable) |
Output Monitoring |
Configuration |
Multiplexed |
Voltage Accuracy |
±10 mV max (sampled at 2 Hz) |
Current Accuracy |
±1 mA, max (sampled at 10 Hz) |
Soft-Start/Stop duration |
256 µS to 5 seconds |
Steady State PWM output |
0 to 100% in 0.4% increments. (Minimum
period is 256 µSec) |
Output Throughput Rate |
1 kHz max |
Power up / reboot state |
Off |
Power dissipation |
< 2 W, not including output switches |
Isolation |
350 Vrms |
Operating Temp. Range |
Tested -40 to +85 °C |
Operating Humidity |
95%, non-condensing |
Vibration |
IEC 60068-2-6 |
5 g, 10-500 Hz, sinusoidal |
IEC 60068-2-64 |
5 g (rms), 10-500 Hz, broad-band random |
Shock IEC 60068-2-27 |
50 g, 3 ms half sine, 18 shocks @ 6 orientations
30 g, 11 ms half sine, 18 shocks @ 6 orientations |
MTBF |
260,000 hours |