Technical Specifications |
Inputs |
Number of channels |
2 |
Configuration |
Synchro (3-wire) or Resolver (4-wire) may be
selected via software |
Resolution |
16-bit |
Accuracy |
± 2.6 arc-minute |
Signal Inputs |
5 - 28 Vrms |
Acceleration |
300 rps/s @ 60 Hz, 450 rps/s @ 400 Hz
1000 rps/s @ 4000 Hz |
Step response |
800 mS - 179° @ 60 Hz, 150 mS - 179° @ 2500 Hz |
Update rate |
Max. rate is equal to the excitation frequency. |
Reference output |
Number of channels |
2 (one per input channel) |
Output voltage |
up to19.8 Vrms at 3.0 VA (see table on following
page for other output voltages) |
Voltage resolution |
16-bit |
Reference Frequency |
50 Hz to 10 kHz (±0.1%) |
Synchro / Resolver Outputs |
Number of channels |
2 (total number of synchro/resolver inputs and
simulated outputs is limited to 2.) |
Configuration |
Synchro (3-wire) or Resolver (4-wire) |
Resolution |
16-bit |
Output Voltage |
up to 19.8 Vrms up to 2.4 VA. (see table) |
Output Accuracy |
±4 arc-minutes |
Output readback and protection |
Output protection |
Automatic shut down on overload |
Voltage output monitoring |
±70 mV, monitored at 1.3 Hz |
Current output monitoring |
±1.0 mA, monitored at 1.3 Hz |
General Specifications |
Operating temperature |
Tested -40 °C to +70 °C |
Vibration |
EC 60068-2-6 |
3 g, 10-500 Hz, sinusoidal |
IEC 60068-2-64 |
3 g (rms), 10-500 Hz, broad-band random |
Shock IEC 60068-2-27 |
50 g, 3 ms half sine, 18 shocks @ 6 orientations
30 g, 11 ms half sine, 18 shocks @ 6 orientations |
Humidity |
5 to 95%, non-condensing |
MTBF |
275,000 hours |
Power consumption |
3.5 Watt with no load
12 Watt maximum |