Logicbus/ Productos/ Ethernet/ Tarjetas para chassis/ Bus CAN/ DNR-CAN-503

Comprar ahora

Logicbus SA de CV

Buscar productos

DNR-CAN-503

DNR-CAN-503
4-port, CAN bus interface board for the PowerDNR RACKtangle®
 
The DNR-CAN-503 is a 4-port high-speed CAN interface for PowerDNA distributed automation and control system. This board (layer) is designed for communication with high-speed CAN devices up to 1 Mb/s. DNR-CAN-503 uses the Philips SJA1000 CAN Controller for advanced functionality such as listen-only, self-reception (echo), and advanced filtering modes and new transceivers for sleep/wakeup mode support.

The DNR-CAN-503 includes drivers and example code for use in Visual Basic, VB .NET, C#, J#, C/C++, OPC, DASYLab, LABVIEW (including Linux/Windows and Real-time), VEE, MATLAB, QNX and Linux.
 
Characteristics:
  • 4 independent CAN ports
  • Up to 1Mbit/sec maximum transfer rate
  • 24MHz base clock
  • Completely independent bit rate settings for every port
  • 250V DC max isolation between ports; ports and circuitry
  • Hot plugging support; error detection
  • Fully compatible with ISO 11898 standard
 
Technical Specifications
General
Number of CAN ports 4, per-channel isolated
Max. transfer rate up to 1Mbit/s, per-channel programmable
CAN transceiver Phillips TJA 1050
CAN controller Phillips SJA 1000
Operating temperature tested -40 °C to +85 °C
Vibration IEC 60068-2-6 5 g, 10-500 Hz, sinusoidal
IEC 60068-2-64 5 g (rms), 10-500 Hz, broad-band random
Shock IEC 60068-2-27 50 g, 3 ms half sine, 18 shocks @ 6 orientations
30 g, 11 ms half sine, 18 shocks @ 6 orientations
Humidity 0 to 95%, non-condensing
Power Dissipation 2 Watts typical, 3 Watts max
CAN Controller
Base clock 24MHz
CAN interface version 2.0B
Receive FIFO size TX: 128 messages, RX: 256 messages
Transmit buffer 11- or 29-bit identifier
Acceptance filter 11- or 29-bit identifier
Error detection interrupts-based
Protection short-circuit to battery, ground; thermal protection;
CANH and CANL protected from automotive electrical transients (ISO 7637)
Available modes Active, Listen Only, Self-Test
Max number of nodes 110